Assume full duty to satisfy all demands of our clients; reach steady advancements by marketing the development of our purchasers; grow to be the final permanent cooperative partner of clientele and maximize the interests of customers for Dc Breaker Dc Spd Surge Protection Device Kit, Dc 400 V Spd, Level 2 Charger 32 Amp, We, with great passion and faithfulness, are willing to provide you with perfect services and striding forward with you to create a bright future.
2021 High quality Spd 2p 40ka 800v - HS2-I-50 Lightning Current Arresters – HONI electric Detail:

Features/Benefifits

Easy installation or retrofifit
Din-rail mountable
Fail-safe /self-protected design
IP20 fifinger-safe design
Small foot print

Plug-in format

HS210-I-50 is the most robust range of Type 1/Class I lightning current arresters, able to discharge energy (current) from a direct lightning strike (10/350) on an external lightning protection system (LPS) or overhead supplies, in accordance with EN/IEC 61643-11. DIN rail monobloc format.
■Suitable as a fifirst step of protection in incoming power supply panels and in areas of high atmospheric exposure.
■Discharges impulse currents with a 10/350 μs waveform: 50 kA per phase.
■Exclusive devices for TNS, TNC, TT , IT earthing systems.
■Exclusive devices which are compatible with Power Line Communication networks.
■Biconnect – two types of terminal: for rigid or flflexible cable and for fork type comb busbar.

Data sheet

TypeTechnical DataNominal line voltage (Un) HS210-I-50 230/400 V (50/60Hz)
Maximum continuous voltage (UC) (L-N)

255V

Maximum continuous voltage (UC) (N-PE)

255V

SPD to EN 61643-11

Type 1

SPD to IEC 61643-11

class I

Lightning impulse current (10/350μs) (Iimp)

50kA

Nominal discharge current (8/20μs) (In)

50kA

Voltage protection level (Up) (L-N)

≤ 2.0kV

Voltage protection level (Up) (N-PE)

≤ 2.0kV

Response time (tA) (L-N)

< 100ns

Response time (tA) (N-PE)

< 100ns

Operating State/Fault Indication

no

Degree of protection

IP 20

Insulating material / flammability class

PA66,UL94 V-0

Temperature range

-40ºC~+80ºC

Altitude

13123 ft [4000m]

Conductor Cross Section (max)

35mm2 (Solid) / 25mm2 (Flexible)

Remote Contacts (RC)

no

Format

Monobloc

For mounting on

DIN rail 35mm

Place of installation

indoor installation

Dimensions

HS2-I-50 Power Surge Protector 001

●The power must be cut off before installation, and live operation is strictly prohibited
●It is recommended to connect a fuse or automatic circuit breaker in series at the front of the lightning protection module
●When installing, please connect according to the installation diagram. Among them, L1, L2, L3 are phase wires, N is the neutral wire, and PE is the ground wire. Do not connect it wrongly. After installation, close the automatic circuit breaker (fuse) switch
●After installation, check whether the lightning protection module is working properly 10350gs, discharge tube type, with window: during use, the fault display window should be checked and checked regularly. When the fault display window is red (or the remote signal terminal of the product with remote signal output alarm signal), it means the lightning protection module In the event of failure, it should be repaired or replaced in time.
●Parallel power supply lightning protection modules should be installed in parallel (Kevin wiring can also be used), or double wiring can be used. Generally, you only need to connect any one of the two wiring posts. The connecting wire must be firm, reliable, short, thick, and straight.


Product detail pictures:

2021 High quality Spd 2p 40ka 800v - HS2-I-50 Lightning Current Arresters – HONI electric detail pictures


Related Product Guide:

As a way to provide you advantage and enlarge our organization, we even have inspectors in QC Crew and guarantee you our greatest assistance and product or service for 2021 High quality Spd 2p 40ka 800v - HS2-I-50 Lightning Current Arresters – HONI electric , The product will supply to all over the world, such as: Malta, Southampton, Bangladesh, With the development and enlargement of mass clients abroad, now we've set up cooperative relationships with many major brands. We've our own factory and also have many reliable and well-cooperated factories in the field. Adhering to the "quality first, customer first, We are provideing high-quality, low-cost items and first-class service to customers. We sincerely hope to establish business relationship with customers from all over the world on the basis of quality, mutually benefit. We welcome OEM projects and designs.
  • Cooperate with you every time is very successful, very happy. Hope that we can have more cooperation!
    5 Stars By Natividad from Georgia - 2017.03.07 13:42
    Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Agustin from Mexico - 2018.09.21 11:44
    Write your message here and send it to us