Fast and great quotations, informed advisers to help you choose the correct product that suits all your preferences, a short creation time, responsible top quality control and different services for paying and shipping affairs for Ac Spd 1p 40ka, Busbar Mcb, 40 Amp Car Charger, Good quality is the key factor for the company to stand out from other competitors. Seeing is Believing, want more information? Just trial on its products!
China wholesale 4.5ka B C Spd - HS2-I-50 Lightning Current Arresters – HONI electric Detail:

Features/Benefifits

Easy installation or retrofifit
Din-rail mountable
Fail-safe /self-protected design
IP20 fifinger-safe design
Small foot print

Plug-in format

HS210-I-50 is the most robust range of Type 1/Class I lightning current arresters, able to discharge energy (current) from a direct lightning strike (10/350) on an external lightning protection system (LPS) or overhead supplies, in accordance with EN/IEC 61643-11. DIN rail monobloc format.
■Suitable as a fifirst step of protection in incoming power supply panels and in areas of high atmospheric exposure.
■Discharges impulse currents with a 10/350 μs waveform: 50 kA per phase.
■Exclusive devices for TNS, TNC, TT , IT earthing systems.
■Exclusive devices which are compatible with Power Line Communication networks.
■Biconnect – two types of terminal: for rigid or flflexible cable and for fork type comb busbar.

Data sheet

TypeTechnical DataNominal line voltage (Un) HS210-I-50 230/400 V (50/60Hz)
Maximum continuous voltage (UC) (L-N)

255V

Maximum continuous voltage (UC) (N-PE)

255V

SPD to EN 61643-11

Type 1

SPD to IEC 61643-11

class I

Lightning impulse current (10/350μs) (Iimp)

50kA

Nominal discharge current (8/20μs) (In)

50kA

Voltage protection level (Up) (L-N)

≤ 2.0kV

Voltage protection level (Up) (N-PE)

≤ 2.0kV

Response time (tA) (L-N)

< 100ns

Response time (tA) (N-PE)

< 100ns

Operating State/Fault Indication

no

Degree of protection

IP 20

Insulating material / flammability class

PA66,UL94 V-0

Temperature range

-40ºC~+80ºC

Altitude

13123 ft [4000m]

Conductor Cross Section (max)

35mm2 (Solid) / 25mm2 (Flexible)

Remote Contacts (RC)

no

Format

Monobloc

For mounting on

DIN rail 35mm

Place of installation

indoor installation

Dimensions

HS2-I-50 Power Surge Protector 001

●The power must be cut off before installation, and live operation is strictly prohibited
●It is recommended to connect a fuse or automatic circuit breaker in series at the front of the lightning protection module
●When installing, please connect according to the installation diagram. Among them, L1, L2, L3 are phase wires, N is the neutral wire, and PE is the ground wire. Do not connect it wrongly. After installation, close the automatic circuit breaker (fuse) switch
●After installation, check whether the lightning protection module is working properly 10350gs, discharge tube type, with window: during use, the fault display window should be checked and checked regularly. When the fault display window is red (or the remote signal terminal of the product with remote signal output alarm signal), it means the lightning protection module In the event of failure, it should be repaired or replaced in time.
●Parallel power supply lightning protection modules should be installed in parallel (Kevin wiring can also be used), or double wiring can be used. Generally, you only need to connect any one of the two wiring posts. The connecting wire must be firm, reliable, short, thick, and straight.


Product detail pictures:

China wholesale 4.5ka B C Spd - HS2-I-50 Lightning Current Arresters – HONI electric detail pictures


Related Product Guide:

With our excellent administration, strong technical capability and strict excellent control method, we carry on to offer our clients with responsible good quality, reasonable costs and great companies. We intention at becoming considered one of your most responsible partners and earning your pleasure for China wholesale 4.5ka B C Spd - HS2-I-50 Lightning Current Arresters – HONI electric , The product will supply to all over the world, such as: Ghana, Kuwait, Saudi Arabia, With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
  • This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
    5 Stars By Christine from Turkmenistan - 2017.11.01 17:04
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Honorio from Albania - 2017.11.01 17:04
    Write your message here and send it to us