Having a sound small business credit score, outstanding after-sales services and modern manufacturing facilities, we've got earned an fantastic reputation among our buyers across the globe for Pd Dongle, Dc Rccb, I60 Rcbo 2p, We are willing to cooperate with business friends from at home and abroad and create a great future together.
Free sample for 2 Pole Spd 1000vdc 20-40 - HS2X-RJ11 Data and Signal Surge Protection – HONI electric Detail:
Features/Benefifits
Easy installation
Fail-safe /self-protected design Very fast response
Hybrid GDT and Diode Technology
10/100/1000 Mbps and Gigabit Compatible High-Speed Protector technology
Bi-Directional Protection
Shielded Enclosure and Connectors
HS2X-RJ11 is the series of devices for discharging transient overvoltages induced in ADSL telephone (fax, modem…) lines, In accordance with IEC 61643-21.In-line
format.
■Suitable for the protection of communications equipment connected to ADSL lines.
By their nature, they are highly exposed to induced transient overvoltages (surges) associated with meteorological activity.
■Protection of a telephone pair.
■Discharge capacity with an 8/20 μs waveform: 3 kA.
■No installation required. It connects directly to the equipment to be protected via RJ11 connectors.
Data sheet
Type
Technical Data Application |
HS2X-RJ11
Telephone Line
|
Bandwith |
up to 10 MHz
|
Nominal voltage (Un) |
150V / 110V / 48V / 24V
|
Maximum continuous operating voltage (UC) |
170V / 150V / 60V / 30V
|
Voltage protection level (8/20μs) (Up) |
≤330V / 300V / 220V / 120V
|
Nominal discharge current (8/20μs) (In) |
3kA
|
Maximumworking current (IL) |
300mA
|
Series resistance (RS) |
15Ω
|
Response time (tA) |
< 10ns
|
Degree of protection |
IP 20
|
protected pairs |
1
|
Pins Protected |
3,4
|
External materials |
Aluminum
|
Temperature range |
-40ºC~+80ºC
|
Altitude |
13123 ft [4000m]
|
Connection (input – output) |
RJ11
|
Type of connection |
Series (two ports)
|
For mounting on |
Optional Din-rail mountable
|
Place of installation |
indoor installation
|
Type of SPD |
C2,C3
|
Product standards |
IEC 61643-21, EN 61643-21
|
Dimensions

Product detail pictures:
Related Product Guide:
Being supported by an innovative and experienced IT team, we could present technical support on pre-sales & after-sales service for Free sample for 2 Pole Spd 1000vdc 20-40 - HS2X-RJ11 Data and Signal Surge Protection – HONI electric , The product will supply to all over the world, such as: Puerto Rico, Botswana, Bhutan, Our well-equipped facilities and excellent quality control throughout all stages of production enable us to guarantee total customer satisfaction. If you are interested in any of our products or would like to discuss a custom order, please feel free to contact me. We are looking forward to forming successful business relationship with new clients around the world.