From the past few years, our firm absorbed and digested sophisticated technologies equally at home and abroad. Meanwhile, our organization staffs a group of experts devoted into the growth of electromagnetic rcbo, 2 Pole Spd 1000vdc, Spd Dc, Our main objectives are to deliver our consumers worldwide with high quality, competitive selling price, satisfied delivery and outstanding providers.
Manufacturer of Dc Spd 1000v Surge Protection Device - HS2T-BNC Data and Signal Surge Protection – HONI electric Detail:
Features/Benefifits
Easy installation
Fail-safe /self-protected design
Very fast response
Hybrid GDT and Diode Technology
Long distance transmission
Good transmission effect
Strong anti-interference
complies IEC 61643-21 standard
SPD for CCTV Camera
HS2T-BNC is the series of devices for discharging transient overvoltages induced in coaxial lines. In accordance with IEC 61643-21. Coaxial format.
■Suitable for the protection of coaxial lines of TV and CCTV systems. By their nature, they are highly exposed to induced transient overvoltages (surges) associated with meteorological activity.
■Discharge capacity with an 8/20 μs waveform: 20 kA.
■No installation required. It connects directly to the equipment to be protected via BNC connectors.
■Available with optional Din-rail mountable.
Data sheet
Type
Technical Data
Application |
HS2T-BNC
CCTV systems
|
Frequency |
100 MHZ
|
Transmission Rate |
16 Mb/s
|
Nominal voltage (Un) |
5V
|
Maximum continuous operating voltage (UC) |
8V
|
Nominal discharge current (8/20μs) (In) |
10kA
|
Maximum discharge current (8/20μs) (Imax) |
20kA
|
Voltage protection level (8/20μs) (Up) |
≤ 120V
|
Maximumworking current (IL) |
300mA
|
Impedance |
75Ω
|
Response time (tA) |
< 10ns
|
Degree of protection |
IP 20
|
External materials |
Aluminum
|
Temperature range |
-40ºC~+80ºC
|
Altitude |
13123 ft [4000m]
|
Connection (input – output) |
BNC
|
Type of connection |
Series (two ports)
|
For mounting on |
Optional Din-rail mountable
|
Place of installation |
indoor installation
|
Type of SPD |
C2,C3
|
Product standards |
IEC 61643-21, EN 61643-21
|
Dimensions

SPD for Telephone Line
Product detail pictures:
Related Product Guide:
"Based on domestic market and expand overseas business" is our development strategy for Manufacturer of Dc Spd 1000v Surge Protection Device - HS2T-BNC Data and Signal Surge Protection – HONI electric , The product will supply to all over the world, such as: Swedish, Cyprus, Benin, We've a skilled sales team, they have mastered the best technology and manufacturing processes, have years of experience in foreign trade sales, with customers able to communicate seamlessly and accurately understand the real needs of customers, providing customers with personalized service and unique merchandise.