HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
PRODUCTS
PRODUCTS
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)
HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)

HB232-40/HB234-25 Residual Current Circuit Breaker (RCCB)

It is electro-mechanical in nature. The highlight here is that:

1.It can be wired in either direction.

2.It is accord with IEC/EN 61008-1 (mains voltage independent RCCB), It is with electro-mechanical release that works safely even without supply voltage or line voltage lower than 50V.

3.Type -A: Protects against special forms of residual pulsating DC which have not been smoothed.

4.Protection of persons against electric shock by direct contact (30 mA).

5.Protection of persons against electric shock by indirect contact (300 mA).

6.Protection of installations against fire risks (300 mA).

7. Provides comprehensive protection to household and commercial distribution systems.


    Technical Data


    Electrical characteristics
    Insulation voltage (Ui)400 V
    Pollution degree3
    Rated impulse withstand voltage (Uimp)4 kV

    Electrical Characteristics


    According to IEC/EN 61008-1
    Surge currentwithstand (8/20 μs)withouttrippingAC and A types (notselective  icon (1)   )1250A

    AC, A,(selective icon (1)   )3 kÂ
    Conditional ratedshort-circuit current(Inc/IDc)With FU 125 A gG fuse10,000 A
    Behaviour in case ofvoltage drop icon (3)Residual current protection down to 0 V accordingto IEC/EN 61008-1 § 3.3.4
    Additional characteristics
    Degree of protectionDevice onlyIP20IP40 with screw shield

    Device in modular enclosureIP40Insulation class II
    Endurance (O-C)Electrical> 2 000 cycles

    Mechanical> 5 000 cycles
    Operatingtemperature icon (2)-25° C to +40° C / -13° F to +104° F
    StoragetemperatureAC, A-40° C to +85° C / -40° F to +185° F


    Dimensions(mm)


    9.jpg


    HB232-40


    10.png


    HB234-25


    11.png

    Online feedback
    Or please use the following table for reference. Our sales representative will contact you within 24 hours. Thank you for your attention to our products
    *
    Name
    *
    Phone
    *
    Email @
    *
    Choose country
    *
    Content